Dec 16, 2019
For the joint length of nickel bars, in order to ensure that the composition of the nickel bars does not change during the lengthening of the nickel bars, tungsten-argon arc welding is generally required for self-fusion welding.
We have worked for a metallurgical company to weld nickel bars with a total length of 3 m and one or two welds. Due to the large cross-section and high quality of the nickel bar, a large penetration depth is required during welding to prevent the entire connection part from falling off due to insufficient weld strength during the electroslag smelting process, resulting in the interruption of the smelting process.